This exercise has fictional lanes and real arithmetic. No antibodies were harmed in the making of the spreadsheet.
For each usable lane, divide the background-corrected target signal by its suitable control signal. Compare those ratios across lanes using the same measurement and background rules. If a band is saturated, the ratio is not interpretable from that image. Keep the raw measurements and document the reason for excluding a result.
Calculate the normalised values
| Lane | Target signal | Control signal | Result |
|---|---|---|---|
| Reference | 180 | 90 | 2.00 |
| Comparison | 240 | 160 | 1.50 |
| Clipped target | Saturated | 100 | Uninterpretable from this image |
The comparison ratio is 1.50 ÷ 2.00 = 0.75, or 25% lower relative to the reference ratio. The raw target was higher in the comparison lane. Both statements can be true because the control changed as well. If the loading control changes for biological reasons or falls outside its useful signal range, this simple normalisation can mislead.
What can you conclude from two lanes?
You can report the calculated ratio for these simulated lanes. You cannot infer reproducibility or significance from one pair. In an actual report, identify the biological replicates, keep the region and background rules visible, and state how saturation was assessed. A spreadsheet can divide almost anything; your job is deciding whether it should.
Compare western blot quantification software · Peer-reviewed software comparison
0 Comments
We will get back to you as soon as possible and thanks for the comment.